PRODUCTS SERIES

  Back-up UPS
2000 Series
  On-line UPS
6000 Series
8000 Series
  EPS
9000 Series
  Communication Power Supply
4000 Series
  Electric Power Supply
3000 Series
  Battery
Valve Regulateo Lead Acid Battery GP Series
Gel Stationary Battery GH Series

 

EPS 9000 Series

 

Specification Table(1/1、3/1)

EU2K~20K(Single in and single out)
Mode:
EU2K
EU3K
EU6K
EU10K
EU15K
EU20K
Capacitg(KW)
20KVA/1.6
3KVA/2.4
6KVA/4.8
10KVA/8
15KVA/12
20KVA/16
Voltage
Single phase with two Lines+ground wire ,220V±25%
Noise
≤52dB(distance 1m)
≤60dB(distance 1m)
Size:
(W×D×Hmm)
530×264×592
630×343×700
Weight(Kg)
(excludingthebattery)
65
70
80
145
160
180
 
EP6K~60K(Three- ins and single out)
Mode:
EP6K
EP10K
EP15K
EP20K
EP30K
EP40K
EP50K
EP60K
Capacitg(KW)
6KVA/4.8
10KVA/8
15KVA/12
20KVA/16
30KVA/24
40KVA/32
50KVA/40
60KVA/48
Voltage
Three phase with four Lines+ground wire,380V±25%
Noise
≤60dB(distance 1m)
≤65dB(distance 1m)
Size:
(W×D×Hmm)
620×343×995
650×700×1510
Weight(Kg)
(excludingthe battery)
130
165
180
220
400
450
530
620

Common parameters(1/1、3/1)

Input
Frequency
50Hz/60Hz±10%
Power actor
≥92%
Output
Voltage
220V±0.5%
Voltage regulation
Stable voltage±1%,dynamic oltage±2%,(0-100% load
fluctuation20ms)
Frequency stableness
50Hz/60Hz±0.5%
Frequency torsion rate
Less than 1Hz / second
Instant load status
± 0.4%(100% instant load fluctuation)
Harmonic distortion
For linear load, less than 3%(full load),total rectifying
harmonics is lass than 5%
Overload capacitance
150%
Wave form
Sine wave

efficiency
Input AC to output AC
Above 91%
Transfer time
Mains power supply fails or restores
0 second
Turns from UPS to BYPASS
Less than 4 ms
Battery
DC Voltage
192V
Charging time
After it is fully charged, it can be filled to 90% of the total capacity after it is charged for 8 hours.
Warning sound
Battery discharge
If the main power fails, it buzzes once every 4 seconds.
If the battery is low, it buzzes once every 0.5 seconds.
If the battery stops discharging, it buzzes continuously.
In fault tatus
Continuously buzzes


Internal
Protecting
device
LCD
panel

Battery
Automatically shuts down the machine when the battery power is low, it has no fuse switch protection.
Overload
After the overload (110~150%) lasts for 30 seconds,it automatically jumps to BYPASS. It can automatically restore normal state.
Temperature is too high
If the internal temperature of the UPS>85°C, it will
automatically jump to BYPASS.
Output short circuit
Limits Current, automatically shuts down the machine, without fuse switch protection.
UPS is abnormal
Automatically jumps to BYPASS mode and starts direct mains power supply.
Noise Filter
10~10KHz at 40 db;100KHz~100MHz at 70db
LCD display
Indicating input and output voltage, frequency; battery voltage and output power (%).
Battery BVL
One LED, it glows when the battery voltage is low.

Outside environment

Temperature
0~40℃
Relative humidity
10%~90% (No condensation)
Operation condition
Lower than 1500 meters above sea level (altitude)

Specification Table(3/3)

 
ET6K~ET60K(Three- ins and Three out)
Mode:
ET6K
ET10K
ET15K
ET20K
ET30K
ET40K
ET50K
ET60K
Capacity(KW)
6KVA/4.8
10KVA/8
15KVA/12
20KVA/16
30KVA/24
40KVA/32
50KVA/40
60KVA/48
Battery voltage(V)
192V
Overall efficiency
≥91%
Noise
≤53dB(distance 1m)
≤56B(distance 1m)
Size: W×D×H(mm)
550×600×1135
650×700×1510
Weight(Kg)(excluding the battery)
260
280
310
340
480
520
560
580
 
ET80K~400K(Three- ins and Three out)
Mode:
ET80K
ET100K
ET120K
ET150K
ET200K
ET250K
ET300K
ET400K
Capacity(KW)
80KVA/64
100KVA/80
120KVA/96
150KVA/120
200KVA/160
250KVA/200
300KVA/240
400KVA/320
Battery voltage(V)
240
384
Overall efficiency
≥93%
≥94%
Noise
≤60dB(distance 1m)
≤65B((distance 1m)
Size: W×D×H(mm)
1250×750×1600
1600×750×1600
Weight(Kg)(excluding the battery)
780
860
980
1250
1600
1800
2100
2500

Common parameters(3/3)

Input
Voltage
Three-phase four-wire system, 380V±25%
Frequency
50Hz±10%
Power factor
≥0.92
Output
Voltage
Three-phase four-wire system, 380V±1%
Frequency
50Hz±0.05%(when power is provided by battery)
Harmonic distortion
Pure sine wave, distortion factor <3% (linear load), <5%( non-linear load)
Unbalanced voltage
Balanced load≤1%, unbalanced load≤3%
Phase displacement angle
Balanced load≤1, unbalanced load≤3
Dynamic transient range
When output is 0~50%~100%≤3%, recovery time ≤10ms
Overload capacity
125%≥10min, 150%≥20s
Peak factor
5:1
Switching time
Pure online zero switching
Battery
Battery type
Lead-acid sealed, maintenance-free
Charging method
PWM constant current and constant voltage, battery intelligent management system
Charging time (standard type)
12 hours
System performance
System performance MTBF
300,000 hours
Environment scope
temperature-10℃~50℃, humidity 0~93% without condensation, altitude ≤3000m
Support software interface
Novell Netware Microsoft Windows9x Windows2000 Windows NT Linux
Other
Dustproof and moisture proof, inverter isolating transformer, thunderbolt surging wave absorption, and manual bypass switch