PRODUCTS SERIES

  Back-up UPS
2000 Series
  On-line UPS
6000 Series
8000 Series
  EPS
9000 Series
  Communication Power Supply
4000 Series
  Electric Power Supply
3000 Series
  Battery
Valve Regulateo Lead Acid Battery GP Series
Gel Stationary Battery GH Series

 

On-line UPS 6000 Series

 

Specification Table

SU1K¡«20K£¨Single in and single out£©
Mode:
SU1K
SU2K
SU3K
SU6K
SU10K
SU15K
SU20K
Capacitg(KW)
1KVA/0.8
2KVA/1.6
3KVA/2.4
6KVA/4.8
10KVA/8
15KVA/12
20KVA/16
Voltage
Single phase with two Lines+ground wire ,220V¡À25%
Battery Voltage
48V
96V
192V
Noise
¡Ü52dB(distance 1m)
¡Ü60dB(distance 1m)
Size:
(W¡ÁD¡ÁHmm)
530¡Á264¡Á592
630¡Á343¡Á725
Weight(Kg)
(excluding the battery)
30
40
45
60
105
130
160
 
SP6K¡«SP60K£¨Three- ins and single out£©
Mode:
SP6K
SP10K
SP15K
SP20K
SP30K
SP40K
SP50K
SP60K
Capacitg(KW)
6KVA/4.8
10KVA/8
15KVA/12
20KVA/16
30KVA/24
40KVA/32
50KVA/40
60KVA/48
Voltage
Three phase with four Lines+ground wire,380V¡À25%
Battery Voltage
192V
336V
Noise
¡Ü60dB(distance 1m)
¡Ü65dB(distance 1m)
Size:
(W¡ÁD¡ÁHmm)
620¡Á343¡Á995
650¡Á700¡Á1510
Weight(Kg)
(excluding the battery)
130
165
190
210
400
450
530
620

Common parameters

Input
Frequency
50Hz/60Hz¡À10%
Power actor
¡Ý95%
Output
Voltage
220V¡À0.5%
Voltage regulation
Stable voltage¡À1%£¬dynamic oltage¡À2%£¬£¨0-100% load
fluctuation20ms£©
Frequency stableness
50Hz/60Hz¡À0.5%
Frequency torsion rate
Less than 1Hz / second
Instant load status
¡À 0.4%(100% instant load fluctuation)
Harmonic distortion
For linear load, less than 3%(full load)£¬total rectifying
harmonics is lass than 5%
Overload capacitance
150%
Wave form
Sine wave

efficiency
Input AC to output AC
Above 95%
Transfer time
Mains power supply fails or restores
0 second
Turns from UPS to BYPASS
Less than 4 ms
Battery
Type
Lead-acid sealed, maintenance-free
Charging time
After it is fully charged, it can be filled to 90% of the total capacity after it is charged for 8 hours.
Warning sound
Battery discharge
If the main power fails, it buzzes once every 4 seconds.
If the battery is low, it buzzes once every 1 seconds.
If the battery stops discharging, it buzzes continuously.
In fault tatus
Continuously buzzes


Internal
Protecting
device
LCD
panel

Battery
Automatically shuts down the machine when the battery power is low, it has no fuse switch protection.
Overload
After the overload (110¡«150%) lasts for 30 seconds,it automatically jumps to BYPASS. It can automatically restore normal state.
Temperature is too high
If the internal temperature of the UPS>85¡ãC, it will
automatically jump to BYPASS.
Output short circuit
Limits Current, automatically shuts down the machine, without fuse switch protection.
UPS is abnormal
Automatically jumps to BYPASS mode and starts direct mains power supply.
Noise Filter
10~10KHz at 40 db£»100KHz~100MHz at 70db
LCD display
Indicating input and output voltage, frequency; battery voltage and output power (%).
Battery BVL
One LED, it glows when the battery voltage is low.

Outside environment

Temperature
-10~50¡æ
Relative humidity
0%~93% (No condensation)
Operation condition
Lower than 3000 meters above sea level (altitude)
Multiple CPU Intelligent Control
Battery Switch-on Function
 
Advanced multiple CPU intelligent control is one digital software processed by microprocessor, can precisely and integrally control UPS data, and provide with enough calculation capacity, so that UPS can be under the best operation at any time.
  The device features its battery switch-on function, at no public power supply for UPS device, the battery can supply with power alternatively, and then provide with stable AC power output, thus more conveniently provide the customer wit flexible solution for power supply.
Advance IGBT inverted technology

 

  Combined advanced IGBT technology with hi-frequency wider-modulated technology (PWM), the technology can reduce systematic noise and power loss, so that customer can obtain hi-quality power output and optimized efficiency under each operation load.
Advanced control design structure
  Advance module design can reduce mean troubleshooting time (MTTR) and keep up best service. and best suitability for 100% 3-phase unbalanced load and non-linear load, must not use the UPS rated capacity under reduced capacity, you can consistently operate under 3-phased 100% unbalanced load.

Intelligent by-pass switch
  UPS can automatically monitor public power voltage under by-pass circuit mode, if input voltage exceeds rated value -20%¡«+50%, it shall automatically terminate its voltage output so as to protect from loaded equipment and UPS itself.

Personal display interface
  Intelligent power management personal display panel is made of mini LCD system, clearly provides with integral operation status while UPS operation, herein LCD shall display public power, battery, output, load and interior status information, thus greatly convenient for operator and user. With remote monitor of RS232 interface and self-test function and timing switching function in this system, the system can realize in monitoring and alarming of each operation status, all information above make it into real intelligent UPS.
Advance phase-balanced technology
 

With most advanced phase-balanced technology now, it features best stability, even if loss-phase, it still operate at normal condition, especially in some worse power supply environment.

Sole parallel redundant structure

  Only fully understandable for the key load of power supply, you can design satisfactory UPS system, the system adopts most advance technology, featured as unique idea and promoted for multiple UPS parallel structure (RPA) so that system optimizes best reliability. This series adopts parallel system to assure each key part of UPS fully controlled, therefore, the parallel redundancy is the best in the property.