Specification
Table
|
SU1K¡«20K£¨Single in and single
out£©
|
|
Mode:
|
SU1K
|
SU2K
|
SU3K
|
SU6K
|
SU10K
|
SU15K
|
SU20K
|
|
Capacitg(KW)
|
1KVA/0.8
|
2KVA/1.6
|
3KVA/2.4
|
6KVA/4.8
|
10KVA/8
|
15KVA/12
|
20KVA/16
|
|
Voltage
|
Single phase with two Lines+ground
wire ,220V¡À25%
|
|
Battery Voltage
|
48V
|
96V
|
192V
|
|
Noise
|
¡Ü52dB(distance 1m)
|
¡Ü60dB(distance 1m)
|
|
Size:
(W¡ÁD¡ÁHmm)
|
530¡Á264¡Á592
|
630¡Á343¡Á725
|
|
Weight(Kg)
(excluding the battery)
|
30
|
40
|
45
|
60
|
105
|
130
|
160
|
|
SP6K¡«SP60K£¨Three- ins and
single out£©
|
|
Mode:
|
SP6K
|
SP10K
|
SP15K
|
SP20K
|
SP30K
|
SP40K
|
SP50K
|
SP60K
|
|
Capacitg(KW)
|
6KVA/4.8
|
10KVA/8
|
15KVA/12
|
20KVA/16
|
30KVA/24
|
40KVA/32
|
50KVA/40
|
60KVA/48
|
|
Voltage
|
Three phase with four Lines+ground
wire,380V¡À25%
|
|
Battery Voltage
|
192V
|
336V
|
|
Noise
|
¡Ü60dB(distance 1m)
|
¡Ü65dB(distance 1m)
|
|
Size:
(W¡ÁD¡ÁHmm)
|
620¡Á343¡Á995
|
650¡Á700¡Á1510
|
|
Weight(Kg)
(excluding the battery)
|
130
|
165
|
190
|
210
|
400
|
450
|
530
|
620
|
Common parameters
|
Input
|
Frequency
|
50Hz/60Hz¡À10%
|
|
Power actor
|
¡Ý95%
|
|
Output
|
Voltage
|
220V¡À0.5%
|
|
Voltage regulation
|
Stable voltage¡À1%£¬dynamic oltage¡À2%£¬£¨0-100%
load
fluctuation20ms£©
|
|
Frequency stableness
|
50Hz/60Hz¡À0.5%
|
|
Frequency torsion rate
|
Less than 1Hz / second
|
|
Instant load status
|
¡À 0.4%(100% instant load fluctuation)
|
|
Harmonic distortion
|
For linear load, less than 3%(full
load)£¬total rectifying
harmonics is lass than 5%
|
|
Overload capacitance
|
150%
|
|
Wave form
|
Sine wave
|
|
|
Input AC to output AC
|
Above 95%
|
|
Transfer time
|
Mains power supply fails or restores
|
0 second
|
|
Turns from UPS to BYPASS
|
Less than 4 ms
|
|
Battery
|
Type
|
Lead-acid sealed, maintenance-free
|
|
Charging time
|
After it is fully charged, it can
be filled to 90% of the total capacity after it
is charged for 8 hours.
|
|
Warning sound
|
Battery discharge
|
If the main power fails, it buzzes
once every 4 seconds.
|
|
If the battery is low, it buzzes once every 1 seconds.
|
|
If the battery stops discharging,
it buzzes continuously.
|
|
In fault tatus
|
Continuously buzzes
|
Internal
Protecting
device
LCD
panel
|
Battery
|
Automatically shuts down the machine
when the battery power is low, it has no fuse switch
protection.
|
|
Overload
|
After the overload (110¡«150%) lasts
for 30 seconds,it automatically jumps to BYPASS.
It can automatically restore normal state.
|
|
Temperature is too high
|
If the internal temperature of the
UPS>85¡ãC, it will
automatically jump to BYPASS.
|
|
Output short circuit
|
Limits Current, automatically shuts
down the machine, without fuse switch protection.
|
|
UPS is abnormal
|
Automatically jumps to BYPASS mode and starts direct mains power
supply.
|
|
Noise Filter
|
10~10KHz at 40 db£»100KHz~100MHz
at 70db
|
|
LCD display
|
Indicating input and output voltage,
frequency; battery voltage and output power (%).
|
|
Battery BVL
|
One LED, it glows when the battery voltage is low.
|
|
|
Temperature
|
-10~50¡æ
|
|
Relative humidity
|
0%~93% (No condensation)
|
|
Operation condition
|
Lower than 3000 meters above sea
level (altitude)
|
|
|
Multiple
CPU Intelligent Control |
|
Battery
Switch-on Function |
| |
Advanced
multiple CPU intelligent control is one digital software
processed by microprocessor, can precisely and integrally
control UPS data, and provide with enough calculation
capacity, so that UPS can be under the best operation
at any time.
|
|
The
device features its battery switch-on function, at no
public power supply for UPS device, the battery can supply
with power alternatively, and then provide with stable
AC power output, thus more conveniently provide the customer
wit flexible solution for power supply. |
 |
Advance
IGBT inverted technology |
|
| |
Combined
advanced IGBT technology with hi-frequency wider-modulated
technology (PWM), the technology can reduce systematic
noise and power loss, so that customer can obtain hi-quality
power output and optimized efficiency under each operation
load. |
 |
Advanced
control design structure |
| |
Advance
module design can reduce mean troubleshooting time (MTTR)
and keep up best service. and best suitability for 100%
3-phase unbalanced load and non-linear load, must not
use the UPS rated capacity under reduced capacity, you
can consistently operate under 3-phased 100% unbalanced
load.
|
|
|
Intelligent
by-pass switch |
| |
UPS
can automatically monitor public power voltage under by-pass
circuit mode, if input voltage exceeds rated value -20%¡«+50%,
it shall automatically terminate its voltage output so
as to protect from loaded equipment and UPS itself. |
|
|
|
Personal
display interface |
| |
Intelligent
power management personal display panel is made of mini
LCD system, clearly provides with integral operation status
while UPS operation, herein LCD shall display public power,
battery, output, load and interior status information,
thus greatly convenient for operator and user. With remote
monitor of RS232 interface and self-test function and
timing switching function in this system, the system can
realize in monitoring and alarming of each operation status,
all information above make it into real intelligent UPS. |
|
|
Advance
phase-balanced technology |
| |
With most
advanced phase-balanced technology now, it features
best stability, even if loss-phase, it still operate
at normal condition, especially in some worse power
supply environment.
|
 |
Sole
parallel redundant structure
|
| |
Only
fully understandable for the key load of power supply,
you can design satisfactory UPS system, the system adopts
most advance technology, featured as unique idea and promoted
for multiple UPS parallel structure (RPA) so that system
optimizes best reliability. This series adopts parallel
system to assure each key part of UPS fully controlled,
therefore, the parallel redundancy is the best in the
property. |
|
|
|