Specification Table(1/1、3/1)

DU2K~20K(Single in and single out)
Mode:
DU2K
DU3K
DU6K
DU10K
DU15K
DU20K
Capacitg(KW)
20KVA/1.6
3KVA/2.4
6KVA/4.8
10KVA/8
15KVA/12
20KVA/16
Voltage
Single phase with two Lines+ground wire ,220V±25%
Noise
≤52dB(distance 1m)
≤60dB(distance 1m)
Size:
(W×D×Hmm)
530×264×592
630×343×700
Weight(Kg)
(excludingthebattery)
65
70
80
145
160
180
 
DP6K~60K(Three- ins and single out)
Mode:
DP6K
DP10K
DP15K
DP20K
DP30K
DP40K
DP50K
DP60K
Capacitg(KW)
6KVA/4.8
10KVA/8
15KVA/12
20KVA/16
30KVA/24
40KVA/32
50KVA/40
60KVA/48
Voltage
Three phase with four Lines+ground wire,380V±25%
Noise
≤60dB(distance 1m)
≤65dB(distance 1m)
Size:
(W×D×Hmm)
620×343×995
650×700×1510
Weight(Kg)
(excludingthe battery)
130
165
180
220
400
450
530
620

Common parameters(1/1、3/1)

Input
Frequency
50Hz/60Hz±10%
Power actor
≥92%
Output
Voltage
220V±0.5%
Voltage regulation
Stable voltage±1%,dynamic oltage±2%,(0-100% load
fluctuation20ms)
Frequency stableness
50Hz/60Hz±0.5%
Frequency torsion rate
Less than 1Hz / second
Instant load status
± 0.4%(100% instant load fluctuation)
Harmonic distortion
For linear load, less than 3%(full load),total rectifying
harmonics is lass than 5%
Overload capacitance
150%
Wave form
Sine wave

efficiency
Input AC to output AC
Above 91%
Transfer time
Mains power supply fails or restores
0 second
Turns from UPS to BYPASS
Less than 4 ms
Battery
DC Voltage
192V
Charging time
After it is fully charged, it can be filled to 90% of the total capacity after it is charged for 8 hours.
Warning sound
Battery discharge
If the main power fails, it buzzes once every 4 seconds.
If the battery is low, it buzzes once every 0.5 seconds.
If the battery stops discharging, it buzzes continuously.
In fault tatus
Continuously buzzes


Internal
Protecting
device
LCD
panel

Battery
Automatically shuts down the machine when the battery power is low, it has no fuse switch protection.
Overload
After the overload (110~150%) lasts for 30 seconds,it automatically jumps to BYPASS. It can automatically restore normal state.
Temperature is too high
If the internal temperature of the UPS>85°C, it will
automatically jump to BYPASS.
Output short circuit
Limits Current, automatically shuts down the machine, without fuse switch protection.
UPS is abnormal
Automatically jumps to BYPASS mode and starts direct mains power supply.
Noise Filter
10~10KHz at 40 db;100KHz~100MHz at 70db
LCD display
Indicating input and output voltage, frequency; battery voltage and output power (%).
Battery BVL
One LED, it glows when the battery voltage is low.

Outside environment

Temperature
0~40℃
Relative humidity
10%~90% (No condensation)
Operation condition
Lower than 1500 meters above sea level (altitude)

Specification Table(3/3)

 
DT6K~60K(Three- ins and Three out)
Mode:
DT6K
DT10K
DT15K
DT20K
DT30K
DT40K
DT50K
DT60K
Capacity(KW)
6KVA/4.8
10KVA/8
15KVA/12
20KVA/16
30KVA/24
40KVA/32
50KVA/40
60KVA/48
Battery voltage(V)
192V
Overall efficiency
≥91%
Noise
≤53dB(distance 1m)
≤56B(distance 1m)
Size: W×D×H(mm)
550×600×1135
650×700×1510
Weight(Kg)(excluding the battery)
260
280
310
340
480
520
560
580
 
DT80K~400K(Three- ins and Three out)
Mode:
DT80K
DT100K
DT120K
DT150K
DT200K
DT250K
DT300K
DT400K
Capacity(KW)
80KVA/64
100KVA/80
120KVA/96
150KVA/120
200KVA/160
250KVA/200
300KVA/240
400KVA/320
Battery voltage(V)
240
384
Overall efficiency
≥93%
≥94%
Noise
≤60dB(distance 1m)
≤65B((distance 1m)
Size: W×D×H(mm)
1250×750×1600
1600×750×1600
Weight(Kg)(excluding the battery)
780
860
980
1250
1600
1800
2100
2500

Common parameters(3/3)

Input
Voltage
Three-phase four-wire system, 380V±25%
Frequency
50Hz±10%
Power factor
≥0.92
Output
Voltage
Three-phase four-wire system, 380V±1%
Frequency
50Hz±0.05%(when power is provided by battery)
Harmonic distortion
Pure sine wave, distortion factor <3% (linear load), <5%( non-linear load)
Unbalanced voltage
Balanced load≤1%, unbalanced load≤3%
Phase displacement angle
Balanced load≤1, unbalanced load≤3
Dynamic transient range
When output is 0~50%~100%≤3%, recovery time ≤10ms
Overload capacity
125%≥10min, 150%≥20s
Peak factor
5:1
Switching time
Pure online zero switching
Battery
Battery type
Lead-acid sealed, maintenance-free
Charging method
PWM constant current and constant voltage, battery intelligent management system
Charging time (standard type)
12 hours
System performance
System performance MTBF
300,000 hours
Environment scope
temperature-10℃~50℃, humidity 0~93% without condensation, altitude ≤3000m
Support software interface
Novell Netware Microsoft Windows9x Windows2000 Windows NT Linux
Other
Dustproof and moisture proof, inverter isolating transformer, thunderbolt surging wave absorption, and manual bypass switch
Multiple CPU Intelligent Control
Battery Switch-on Function
 
Advanced multiple CPU intelligent control is one digital software processed by microprocessor, can precisely and integrally control UPS data, and provide with enough calculation capacity, so that UPS can be under the best operation at any time.
  The device features its battery switch-on function, at no public power supply for UPS device, the battery can supply with power alternatively, and then provide with stable AC power output, thus more conveniently provide the customer wit flexible solution for power supply.
Advance IGBT inverted technology

 

  Combined advanced IGBT technology with hi-frequency wider-modulated technology (PWM), the technology can reduce systematic noise and power loss, so that customer can obtain hi-quality power output and optimized efficiency under each operation load.
Advanced control design structure
  Advance module design can reduce mean troubleshooting time (MTTR) and keep up best service. and best suitability for 100% 3-phase unbalanced load and non-linear load, must not use the UPS rated capacity under reduced capacity, you can consistently operate under 3-phased 100% unbalanced load.

Intelligent by-pass switch
  UPS can automatically monitor public power voltage under by-pass circuit mode, if input voltage exceeds rated value -20%~+50%, it shall automatically terminate its voltage output so as to protect from loaded equipment and UPS itself.

Personal display interface
  Intelligent power management personal display panel is made of mini LCD system, clearly provides with integral operation status while UPS operation, herein LCD shall display public power, battery, output, load and interior status information, thus greatly convenient for operator and user. With remote monitor of RS232 interface and self-test function and timing switching function in this system, the system can realize in monitoring and alarming of each operation status, all information above make it into real intelligent UPS.
Advance phase-balanced technology
 

With most advanced phase-balanced technology now, it features best stability, even if loss-phase, it still operate at normal condition, especially in some worse power supply environment.

Sole parallel redundant structure

  Only fully understandable for the key load of power supply, you can design satisfactory UPS system, the system adopts most advance technology, featured as unique idea and promoted for multiple UPS parallel structure (RPA) so that system optimizes best reliability. This series adopts parallel system to assure each key part of UPS fully controlled, therefore, the parallel redundancy is the best in the property.