Multiple
CPU Intelligent Control |
|
Battery
Switch-on Function |
| |
Advanced
multiple CPU intelligent control is one
digital software processed by microprocessor,
can precisely and integrally control UPS
data, and provide with enough calculation
capacity, so that UPS can be under the best
operation at any time.
|
|
The
device features its battery switch-on function,
at no public power supply for UPS device,
the battery can supply with power alternatively,
and then provide with stable AC power output,
thus more conveniently provide the customer
wit flexible solution for power supply. |
 |
Advance
IGBT inverted technology |
|
| |
Combined
advanced IGBT technology with hi-frequency
wider-modulated technology (PWM), the technology
can reduce systematic noise and power loss,
so that customer can obtain hi-quality power
output and optimized efficiency under each
operation load. |
 |
Advanced
control design structure |
| |
Advance
module design can reduce mean troubleshooting
time (MTTR) and keep up best service. and
best suitability for 100% 3-phase unbalanced
load and non-linear load, must not use the
UPS rated capacity under reduced capacity,
you can consistently operate under 3-phased
100% unbalanced load.
|
|
|
Intelligent
by-pass switch |
| |
UPS
can automatically monitor public power voltage
under by-pass circuit mode, if input voltage
exceeds rated value -20%¡«+50%, it shall automatically
terminate its voltage output so as to protect
from loaded equipment and UPS itself. |
|
|
|
Personal
display interface |
| |
Intelligent
power management personal display panel is
made of mini LCD system, clearly provides
with integral operation status while UPS operation,
herein LCD shall display public power, battery,
output, load and interior status information,
thus greatly convenient for operator and user.
With remote monitor of RS232 interface and
self-test function and timing switching function
in this system, the system can realize in
monitoring and alarming of each operation
status, all information above make it into
real intelligent UPS. |
|
|
Advance
phase-balanced technology |
| |
With
most advanced phase-balanced technology
now, it features best stability, even if
loss-phase, it still operate at normal condition,
especially in some worse power supply environment.
|
 |
Sole
parallel redundant structure
|
| |
Only
fully understandable for the key load of power
supply, you can design satisfactory UPS system,
the system adopts most advance technology,
featured as unique idea and promoted for multiple
UPS parallel structure (RPA) so that system
optimizes best reliability. This series adopts
parallel system to assure each key part of
UPS fully controlled, therefore, the parallel
redundancy is the best in the property. |